The UNI-T UT8806E is a professional 6½-digit desktop digital multimeter designed for laboratories, research & development, calibration, industrial testing, and automated measurement systems. Featuring an ultra-high resolution of up to 2,000,000 counts, exceptional 0.0035% DC voltage accuracy, and a fast measurement rate of up to 10,000 readings per second, the UT8806E delivers reliable and highly accurate results for demanding applications.
Equipped with a bright 4.3-inch TFT LCD (480 × 272), the UT8806E supports multiple display modes including numeric display, bar graph, histogram, and trend graph for improved data visualization. Built-in USB, LAN, and RS-232 interfaces, along with optional GPIB support and SCPI remote control, make it an excellent choice for automated testing environments.
| Specification | Details |
|---|---|
| Brand | UNI-T |
| Model | UT8806E |
| Display | 4.3-inch TFT LCD |
| Resolution | 480 × 272 |
| Digits | 6½ Digit |
| Maximum Counts | 2,000,000 Counts |
| DC Voltage Range | 200mV – 1000V |
| AC Voltage | Supported |
| DC Current | 2µA – 10A |
| AC Current | Supported |
| Resistance | 20Ω – 1GΩ |
| Capacitance | 2nF – 100mF |
| Frequency | Up to 300kHz |
| Operating Temperature | 0°C – 40°C |
| Dimensions | 256 × 113.2 × 378.2 mm |
| Connectivity | USB Host, USB Device, LAN, RS-232, Optional GPIB |
| Remote Control | SCPI Supported |
.





Specification | Details |
Product Name | UNI-T UT-P21 |
Model Number | UT-P21 |
Brand Name | UNI-T |
DIY Supplies | Electrical |
Electronic | No |
Semi-finished Product | No |
High-concerned Chemical | None |
Certification | None |
Origin | Mainland China |
Item | Details |
Product Type | Electrical Accessory |
Manufacturer | UNI-T |
Application | Electrical Testing & Measurement |
Condition | New |
Item | Quantity |
UNI-T UT-P21 Accessory | 1 Pc* |
User Documentation | 1 Pc* |
* Actual box contents may vary depending on the product version and supplier package.


Attribute | Details |
Type | Other |
Application | Other |
Accuracy Class | High Accuracy |
Voltage | Other |
Protection Class | Other |
Warranty | 1 Year |
Attribute | Details |
Brand | UNI-T |
Model Number | UT-P30 |
Item Number | UT-P30 |
Product Type | Differential Probe |
Color Classification | UT-P30 Differential Probe 100MHz / 800V |
Type | Other |
Application | Laboratory |
Accuracy Class | High Accuracy |
Accuracy | Other |
Voltage | Other |
Protection Class | Other |
Customized Support | OEM, Other |
Power | / |
Warranty | 1 Year |
Place of Origin | Guangdong, China |
Keyword | Measurement Instrument |
Storage | USB Waveforms, Set Files |
Communication Interface | RS232C/RS485, USB Device, USB Host, Handler |
Lock Function | Data Lock |
Measurement Speed | 3 times/sec (DC); 2 times/sec (Harmonic Function On) |
Item | Details |
Selling Units | Single Item |
Package Length (L) | 46 cm |
Package Width (W) | 38 cm |
Package Height (H) | 28 cm |
Gross Weight | 5.0 kg |
Item | Quantity |
UNI-T UT-P30 Differential Probe | 1 Pc |
Test Leads & Accessories* | 1 Set* |
User Manual* | 1 Pc* |
* Actual package contents may vary depending on the supplier and package version.





UT-P31
High voltage differential probe: (100:1/1000:1) Bandwidth: 100MHz differential voltage: 1500Vpp
The high-voltage differential probe offers selectable ratios of (10:1/100:1), a bandwidth of 100MHz, and the capability to handle differential voltages of ±1500Vpp. This probe is designed for precise and high-frequency measurements in applications requiring the analysis of significant voltage differentials. Before use, it is essential to review the safety instructions provided in the user guide.
The UNI-T UT-P31 Differential Probe provides a safe and reliable measurement solution for use with oscilloscopes. It converts high differential input voltages (≤1500V Peak) into a low-voltage signal (≤7V) that can be displayed and analyzed on an oscilloscope. With a bandwidth of up to 100MHz, it is ideal for high-power testing, research and development, troubleshooting, and maintenance applications.
The probe's attenuation values are specified for oscilloscopes with a 1MΩ input impedance. When used with a 50Ω terminator, the attenuation factor becomes twice the indicated value.
For extended applications, the UT-P31 can also be used with the PL-10 Impedance Converter, allowing more accurate voltage measurements using a digital multimeter. While a typical oscilloscope offers approximately 1% accuracy, a digital multimeter can provide significantly higher measurement precision.
Specification | Details |
Product Name | UNI-T UT-P31 Differential Probe |
Probe Type | Differential Oscilloscope Probe |
Bandwidth | DC to 100 MHz |
Attenuation Ratios | ×100, ×1000 |
Accuracy | ±1% |
Maximum Differential Input Voltage | ≤1500V Peak |
Maximum Output Voltage | ≤7V |
Oscilloscope Input Impedance | 1MΩ (rated attenuation) |
Recommended Accessory | PL-10 Impedance Converter |
Applications | High-Power Testing, R&D, Maintenance, Troubleshooting |
Applications:
UT-P31 1.Features The UT-P31 differential probe provides a safety means for measuring differential voltage to all models of oscilloscopes.It can convert the high differential voltage(≤1500Vp-p) into a low voltage(≤7V)and display on the oscilloscope.Its bandwidth is up to 100MHz,which is ideal for big power testing,development and maintain. The UT-P31 is designed to operate with the 1MΩ impedance oscilloscopes. When combine with the 50Ω load , the attenuation will be 2 times. UT-P31 is recommend to use with our own manufactured PL-10 to expand the measuring with the electricity meter to observe more accurate measurement.The accuracy of oscilloscope is 1% and the electricity meter is about 10 times) 2.Specifications (1) Bandwidth:DC-100MHz (2) Attenuation: X100,X1000 (3) Accuracy:+/-1% (4) Input voltage range(DC+AC PEAK TO PEAK) ≤150Vfor x100, (about 50V RMS ) 5≤1500Vfor x1000, (about 500V RMS ) (5) Permitted max input voltage: Max differential voltage: 1500V(DC+AC PEAKTOPEAK) Max voltage between each input terminal and ground: 5KV RMS(6)Input Impedance: Differential: 8MΩ /1pF Between terminal and ground:4MΩ /2pF(7)Output voltage: ≤7V(8)Output impedance: 50Ω (9) Rise time: 3.5ns for x100 3.5ns for x10 (10)Rejection rate on common mode: 60Hz:>80dB;100Hz:>60dB;1MHz:>50dB (11)Power Supply:Only External 6V DC power supply. (12)Consumption: 150mAmax (0.9 Watt)